Loading...
ARC 2019-06-17_08a Verizon Village CUP MEMORANDUM TO: ARCHITECTURAL REVIEW COMMITTEE FROM: MATTHEW DOWNING, PLANNING MANAGER SUBJECT: CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19- 001; NEW SMALL CELL TELECOMMUNICATION FACILITY ON PRIVATE PROPERTY; LOCATION – 119 E. BRANCH STREET; APPLICANT – VERIZON WIRELESS; REPRESENTATIVE – TRICIA KNIGHT DATE: JUNE 17, 2019 SUMMARY OF ACTION: Approval of the project would allow a small cell telecommunication facility to be installed on private property in the Village. IMPACT ON FINANCIAL AND PERSONNEL RESOURCES: None. RECOMMENDATION: It is recommended that the Architectural Review Committee (ARC) review the proposed project and make a recommendation for approval to the Planning Commission. BACKGROUND: The ARC reviewed the proposed project on May 6, 2019 (Attachments 1 & 2). At that time, members of the ARC were hesitant to make a recommendation on the application due to questions and concerns arising from the proposal and the unavailability of a project representative to respond to the concerns. Specifically, these concerns and preferences were: 1. A preference to locate all of the small cell equipment behind the building’s parapet; 2. If an awning remains proposed, the awning should be striped to better match the first floor awning; 3. A preference for an awning design that reflected the window arches, as they are a unique feature of the building; and 4. A loose, scalloped valance needs to be included with an awning. These items were provided to the applicant’s representative and the project has been revised to address these items. Item 8.a. - Page 1 ARCHITECTURAL REVIEW COMMITTEE CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19-001 JUNE 17, 2019 PAGE 2 ANALYSIS OF ISSUES: The updated proposal includes a three-arched awning-type structure that will follow the existing arches of the building. It is being referenced as an awning-type structure as the structure is largely made of fiberglass painted to match the cloth awnings on the lower floor. The proposal also includes a loose, black valance that will be made of cloth and include the “Skin Care Clinic” copy from the previous awning. The wireless panel antennas remain located under the awning as previously proposed. The Design Guidelines identify that awnings should be compatible in color and design with that of the building. Based on the previous feedback from the ARC, the revised awning design and color achieve the compatibility directed by the Design Guidelines. However, the clarification that the awning is necessary to be fiberglass is not consistent with the Design Guidelines, which specifically say that “Aluminum, fiberglass and plastic awnings or canopies are not appropriate (see Page 38). ADVANTAGES: The proposed project will increase cellular data capacity in the vicinity of the Village, allowing the applicant to continue to serve its customers as they have come to expect. The new awning will also replace a dilapidated awning in the same location. DISADVANTAGES: The use of fiberglass as the primary awning material is not consistent with the Design Guidelines. ENVIRONMENTAL REVIEW: The project has been reviewed in compliance with the California Environmental Quality Act (CEQA), the State CEQA Guidelines, and has been determined to be categorically exempt pursuant to Sections 15301(e)(2), 15303(c), and 15332 of the CEQA Guidelines regarding existing facilities, new construction, and in-fill development projects in urban areas. PUBLIC NOTIFICATION AND COMMENT: The Agenda was posted at City Hall and on the City’s website in accordance with Government Code Section 54954.2. No comments have been received regarding the proposed project. Attachments: 1. May 6, 2019 staff report 2. Minutes from the May 6, 2019 Architectural Review Committee meeting 3. Revised photo simulations 4. Revised project plans Item 8.a. - Page 2 MEMORANDUM TO: ARCHITECTURAL REVIEW COMMITTEE FROM: MATTHEW DOWNING, PLANNING MANAGER SUBJECT: CONSIDERATION OF CONDITIONAL USE PERMIT 19-001; NEW SMALL CELL TELECOMMUNICATION FACILITY ON PRIVATE PROPERTY; LOCATION – 119 E. BRANCH STREET; APPLICANT – VERIZON WIRELESS; REPRESENTATIVE – TRICIA KNIGHT DATE: MAY 6, 2019 SUMMARY OF ACTION: Approval of the project would allow a small cell telecommunication facility to be installed on private property in the Village. IMPACT ON FINANCIAL AND PERSONNEL RESOURCES: None. RECOMMENDATION: It is recommended that the Architectural Review Committee review the proposed project and make a recommendation for approval to the Planning Commission. BACKGROUND: The subject property is a previously developed commercial parcel located in Village Core Downtown (VCD) zoning district (Attachment 1). The parcel is developed with an existing commercial building surrounded by commercial development to the south, east, and west and parking facilities to the north. The applicant proposes the installation of a small cell wireless telecommunication facility, which requires a Conditional Use Permit. Additionally, due to the project’s location in the Village, compliance with the Design Guidelines and Standards for the Historic Character Overlay District D-2.4 (the “Design Guidelines”) is also required (Attachment 2). Lastly, the City’s Telecommunication Facilities Siting and Permit Submittal Requirements require ARC review for small cell facilities proposed in the VCD. Staff Advisory Committee: The Staff Advisory Committee (SAC) reviewed the proposed project on January 17, 2019. Members of the SAC include representatives from the City’s Public Works Department, Police Department, Five Cities Fire Authority, Building Division, Engineering Division, and Planning Division. Members of the SAC were in support of the project as proposed. ATTACHMENT 1 Item 8.a. - Page 3 ARCHITECTURAL REVIEW COMMITTEE CONSIDERATION OF CONDITIONAL USE PERMIT 19-001 MAY 6, 2019 PAGE 2 ANALYSIS OF ISSUES: The purpose of the proposed facility is to improve data and 4G voice capacity that began to quickly slow in mid-2016, due to 4G data traffic growing at about 50% a year. The applicant indicates that improved capacity is essential to keep service at the quality its customers expect. The proposed facility would replace an existing, dilapidated awning on the second story of the building facing E. Branch Street (Attachment 3). The new faux awning is proposed to be a rectangular design with taut red fabric and would continue to include the “Skin Care Clinic” copy from the previous awning. The faux awning would be installed to cover the rounded building details above the windows. The antennas themselves are proposed to be shielded from the underside, to ensure passersby on the sidewalk cannot see them, to the maximum extent possible. Cab ling to the control equipment would be hidden, running through the upper portion of the roof to the rear of the building where the control equipment is proposed to be mounted. The control equipment is proposed to be located in a new equipment cabinet at the rear of the structure and painted to match the color of the building. The Design Guidelines identify that awnings should be compatible in color and design with that of the building. The existing, dilapidated awning is currently red, and other red awnings are in the area. The Design Guidelines also encourage the inclusion of loose valances in awnings, which is consistent with how the ARC has reviewed other awnings in the past. While the proposal does not include a loose valance, it is recommended that the ARC consider including the requirement in a recommendation to the Planning Commission. ADVANTAGES: The proposed project will increase cellular data capacity in the vicinity of the Village, allowing the applicant to continue to serve its customers as they have come to expect. The new awning will also replace a dilapidated awning in the same location. DISADVANTAGES: The lack of loose valance on the awning is not consistent with the Design Guidelines and past ARC practice. However, this can be addressed by requiring a loose valance in the Committee’s recommendation to the Planning Commission . ENVIRONMENTAL REVIEW: The project has been reviewed in compliance with the California Environmental Quality Act (CEQA), the State CEQA Guidelines, and has been det ermined to be categorically exempt pursuant to Sections 15301(e)(2), 15303(c), and 15332 of the CEQA Guidelines regarding existing facilities, new construction, and in-fill development projects in urban areas. Item 8.a. - Page 4 ARCHITECTURAL REVIEW COMMITTEE CONSIDERATION OF CONDITIONAL USE PERMIT 19-001 MAY 6, 2019 PAGE 3 PUBLIC NOTIFICATION AND COMMENT: The Agenda was posted at City Hall and on the City’s website in accordance with Government Code Section 54954.2. No comments have been received regarding the proposed project. Attachments: 1.Vicinity map 2.Page 38 of the Village Design Guidelines 3.Photo simulations 4.Project plans Item 8.a. - Page 5 SUBJECT PROPERTY Item 8.a. - Page 6 C ITY OF A RROYO G RANDE GUIDELINES & S TANDARDS FOR H ISTORIC D ISTRICTS Sign Illumination 1.Signs may be externally illuminated with incandescent lights, or other lighting that does not produce glare and is designed to conserve energy. 2.Wall, canopy, or projecting signs may be illuminated from concealed sources or exposed ornamental fixtures that complement the building’s architecture. 3.Window signs and window displays may be illuminated from concealed sources. 4.Neon tubing signs that approximate the appearance of historic neon are subject to approval of the Architectural Review Committee. All neon tubing shall be covered with transparent or translucent material to prevent rupture or shall be certified by the manufacturer for safety. AWNINGS AND CANOPIES 1.Under-awning or under-canopy signs oriented to pedestrian traffic are encouraged as part of the overall signage in the Village Core Downtown and Mixed Use districts. 2.All graphics, logos, and signs contained on awnings or canopies shall be considered part of the total allowed sign area as defined in the Development Code. 3.Awning or canopy color and design should be compatible with that of the building on which it is attached and complement those of adjacent buildings, both in style and color. 4.Canopies and awnings shall be consistent with the historic period in regard to size, shape, and materials. Aluminum, fiberglass and plastic awnings or canopies are not appropriate. The use of loose valances and traditional vintage-stripped awning material is encouraged. Canopies and awnings consisting of materials stretched taut over a rigid framework are not appropriate. REAR ENTRIES 1.Rear entries are traditionally plain and unadorned. Common materials include brick, stone, boards and battens and wood siding, and these are acceptable for new construction or renovation. 38 Item 8.a. - Page 7 ,. " ver1zon EXISTING l!lT AAR.aYO��SCt NL'iltemi 11H f21 E:, BRN{Otl ST ARRO'l'O�E:.CA� 1RECEIVED JAiN 14 2019 COMMUNf fY DEVELOP MENTCITY OF AR ROYO GRANDE NEW __ ,.,_,.,... _CA_ ,� ... Item 8.a. - Page 8 • • PHOTOSIMULA TION VIEWPOINT 2 verizon✓ DT ARROYO GRANDE SC1 PSL#285338 119& 121 E . BRANCH ST ARROYO GRANDE, CA 93420 ffi~ '-Ul...1 WIRELESS s .. L ~E r,E~IG!'I/ ,;rwu.-INC. SCl1S SHOREHAM Pl.ACE. SUITE 150 SAN OEGO, CA82122 --- Item 8.a. - Page 9 DT ARROYO GRANDE SC1CONSTRUCTION:RADIO:VERIZON SIGNATURE BLOCKDISCIPLINE:SIGNATURE:DATE:EQUIPMENT:SITE ACQUISITION:MICROWAVE:TELCO:WO ADMINISTRATOR:PROJECT ADMINISTRATOR:CODE COMPLIANCEPSL # 285338119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420DRIVING DIRECTIONSTO: 119 & 121 E. BRANCH ST. ARROYO GRANDE, CA 93420VICINITY MAPFROM: 2785 MITCHELL DR.WALNUT CREEK, CA 94958T-1A-1.1A-4SHEETT-1DESCRIPTIONTITLE SHEETREVPLANNER:CONSTRUCTION:SAC WIRELESS SIGNATURE BLOCKDISCIPLINE:SIGNATURE:SITE ACQUISITION:LANDLORD:NEW & EXISTING SOUTHEAST ELEVATIONCALL 811RCallbefore you dig.below.Know what'sCONTRACTOR TO CALL TOVERIFY UTILITIES ATLEAST TWO WORKINGDAYS PRIOR TO DIGGINGWWW.CALL811.COM SITE PLANDATE:A-3EQUIPMENT & ANTENNA PLANZONING DRAWINGS - NOT FOR CONSTRUCTIONPROJECT SUMMARYPROJECT TEAMSMITHCO SURVEYING ENGINEERINGP.O. BOX 81626BAKERSFIELD, CA 93380CONTACT: GREG SMITH, PLSTELEPHONE: (661) 393-1217ARCHITECT:SURVEYOR:UTILITY COORDINATOR:SAC WIRELESS, LLC.NESTOR POPOWYCH, AIA5015 SHOREHAM PL, SUITE 150SAN DIEGO, CA 92122CONTACT: OMAR MUNOZTELEPHONE: (619) 736-3588PLANNINGSITE ACQUISITIONTITLE SHEETA-5NEW & EXISTING SOUTHWEST ELEVATIONC-1 SITE SURVEYPROPERTY INFORMATION:SITE NAME: DT ARROYO GRANDE SC1SITE NUMBER: 285338SITE ADDRESS: 119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420JURISDICTION: CITY OF ARROYO GRANDEASSESSOR'S PARCEL NUMBERCURRENT ZONING:TYPE OF CONSTRUCTION:AREA OF CONSTRUCTION:HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMANHABITATION. HANDICAPPED ACCESS NOT REQUIRED.V-B007-192-056 AND 007-192-057GEODETIC COORDINATESLAT.LONG.ELEVATION.VILLAGE CORE DOWNTOWNCONSTRUCTION INFORMATION35° 07' 25.48"120° 34' 41.98"126.4' NAVD 88(BASIS OF DRAWING)OCCUPANCY:UAPPLICANT/LESSEE2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598OFFICE: (925) 279-6000APPLICANT'S REPRESENTATIVE1. HEAD NORTHEAST ON MITCHELL DR TOWARD OAK GROVE RD2. TURN RIGHT ONTO OAK GROVE RD3. TURN RIGHT ONTO YGNACIO VALLEY RD4. YGNACIO VALLEY RD TURNS RIGHT AND BECOMES HILLSIDE AVE5. USE THE LEFT 2 LANES TO TURN LEFT ONTO THE INTERSTATE 680 S RAMP TO SAN JOSE6. MERGE ONTO I-680 S7. TAKE THE ANDRADE RD EXIT TOWARD SHERIDAN RD8. CONTINUE ONTO MISSION RD9. MERGE ONTO I-680 S VIA THE RAMP TO FREMONT/SAN JOSE10. USE THE RIGHT 3 LANES TO MERGE ONTO US-101 S TOWARD LOS ANGELES11. CONTINUE STRAIGHT TO STAY ON US-101 S12. TAKE EXIT 187A FOR CA-227/GRAND AVE13. TURN LEFT ONTO CA-227 N/E GRAND AVETEK CONSULTING INC.PERMIT PROCESSING SERVICES123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221FAX: (805) 888-2807TEK-CONSULTING.NETC-2 SITE SURVEYSAC WIRELESS1057 LA VISTA ROADSANTA BARBARA, CA 93110CONTACT: CRAIG ENGELTELEPHONE: (805) 440-0038TEK CONSULTING INC.123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221TEK-CONSULTING.NETGENERAL CONTRACTOR NOTESDO NOT SCALE DRAWINGS IF NOT FULL SIZE (24 X 36)CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ONTHE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANYDISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THESAME.PROJECT DESCRIPTIONTHIS PROJECT IS A VERIZON UNMANNED TELECOMMUNICATION WIRELESSFACILITY. IT WILL CONSIST OF THE FOLLOWING:x(2) NEW ANTENNASx(4) NEW RRU'Sx(4) NEW DUAL DIPLEXERSx(1) NEW EQUIPMENT CABINETx(1) NEW GPS ANTENNAxNEW FRP SCREEN / FAUX AWNINGxNEW ELECTRICAL METERPROPERTY OWNER:OWNER: ADNAN EL-HELOUADDRESS: 224 CHRISTINE WAYPISMO BEACH, CA 93449CONTACT: ADNAN EL-HELOUTELEPHONE: 805-801-7464EMAIL:aelhelou@sbcglobal.netSITESHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALA-2ENLARGED ROOF PLAN166NORTHSAC WIRELESS, LLC.8880 CAL CENTER DRIVESUITE 130SACRAMENTO, CA 95826CONTACT: JOSEPH SHARPTELEPHONE: (916) 205-9305JOSEPH.SHARP@SACW.COMA-6DETAILSx2016 CALIFORNIA ADMINISTRATIVE CODEx2016 CALIFORNIA BUILDING CODESx2016 CALIFORNIA ELECTRICAL CODEx2016 CALIFORNIA FIRE CODEx2016 CALIFORNIA ENERGY CODExCITY & COUNTY ORDINANCES111111A-1500FT RADIUS MAP1Item 8.a. - Page 10 Item 8.a. - Page 11 Item 8.a. - Page 12 500FT RADIUS MAP500FT RADIUS MAP1" = 50'-0" (24x36)(OR)SCALE:1/2" = 50'-0" (11x17)50'25' 50'0A-11NORTHSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALVERIZON SITERADIUS= 500FTItem 8.a. - Page 13 9090 SITE PLANSITE PLAN1/2" = 20'-0" (11x17)SCALE:(OR)1" = 20'-0" (24x36)20' 10' 20'0A-1.11NORTHSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALCL1A-2NEW VERIZON WIRELESSANTENNA & EQUIPMENT AREA,SEE ENLARGED ROOF PLAN"ALPHA" SECTOR 105°"BETA" SECTOR 210°E. BRANCH STREETC LNEVAD A S T R E E TCLLE POINT STREETAPN:007-192-007APN:007-192-008APN:007-192-009APN:007-192-010APN:007-192-067APN:007-192-066APN:007-192-062OWNER: CITY OFARROYO GRANDEAPN:007-192-056APN:007-192-057EXISTING UTILITY POLE #37(NEW VERIZON POWER/FIBER P.O.C.)EXISTING OVERHEADPOWER LINEEXISTING UTILITYPOLENOTE:POWER PLAN: PG&E DESIGN TO BEDETERMINEDTRANSPORT SOLUTION: DESIGN TO BEDETERMINEDLESSEE PROPOSED 12'-0"WIDE ACCESS EASEMENTRIGHT-OF- WAYPROPERTY LINERIGHT OF WAYNEW VERIZON POWER/FIBEROVERHEAD LINES (LENGTH=±100FT)Item 8.a. - Page 14 90 90 ENLARGEDROOF PLANENLARGED ROOF PLAN1/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-21NORTHNEW VERIZON WIRELESSEQUIPMENT AREASHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTAL1A-31A-51A-4NOTE:POWER PLAN: PG&E DESIGN TO BEDETERMINEDTRANSPORT SOLUTION: DESIGN TO BEDETERMINEDNEW VERIZON WIRELESSANTENNA AREA2A-3NEW VERIZONWIRELESS FIBER,DC POWER &GROUNDCONDUITS ONSLEEPERS(APPROX. 100')EXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056APN:007-192-057EXISTING RETAININGWALLACUNITACUNITACUNITROOFACCESSHATCHEXISTING 1/2" DIA.CONDUITPROP E R T Y LI N E PROPERTY LINEPROP E R T Y LI N E 2A-52A-4EXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGPROPERTY LINERIGHT OF WAYLESSEE PROPOSED 12'-0"WIDE ACCESS EASEMENTRIGHT-OF- WAYAPN:007-192-055APN:007-192-062OWNER: CITY OFARROYO GRANDE"BETA" SECTOR 210°NEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)"ALPHA" SECTOR 105°Item 8.a. - Page 15 EQUIPMENT &ANTENNA PLANANTENNA PLAN1/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)06"1' 2'2A-3SHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALEQUIPMENT PLAN1/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)06"1' 2'1NEW VERIZON WIRELESS EQUIPMENTCABINET MOUNTED ON NEW CONCRETEPAD LOCATED AT GROUND LEVELNEW VERIZON WIRELESS RRUS,(4)TOTAL, MOUNTED TO EXISTINGBUILDING WITHIN NEW ENCLOSURES(NO TOP OR BOTTOM ENCLOSUREFOR VENTILATION PURPOSES)NORTHNEW VERIZON WIRELESS PANELANTENNAS MOUNTED BEHIND NEW FRPSCREEN (FAUX AWNING), (2) TOTALNORTH15'-0"NEW VERIZON WIRELESS FRP SCREENING (NEW FAUX AWNING)NEW VERIZON WIRELESS LEASE AREANEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')EXISTING 1/2" DIA. CONDUITEXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056APN:007-192-057EXISTING ROOFACCESS HATCHEXISTING AC UNITEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056EXISTINGBUILDINGROOFTOPAPN:007-192-057EXISTINGGROUNDLEVEL3'-4"NEWVERIZON WIRELESSLEASE AREA3'-7"NEWVERIZON WIRELESSLEASE AREA3'-4"EXISTING ELECTRICAL METERNEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINENEW VERIZON WIRELESS METERPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINENEW VERIZON WIRELESS CONDUIT PENETRATIONSNEW VERIZONWIRELESS 17x30FIBER PULL BOXNEW VERIZON WIRELESS 4" FIBER CONDUITROUTE TO NEW EQUIPMENT CABINETNEW VERIZON WIRELESS GPSANTENNA MOUNTED (ABOVE)ON EXISTING BUILDINGEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGEXISTING WEATHER HEAD (ABOVE)MOUNTED TO EXISTING BUILDINGEXISTING RETAINING WALL4A-63A-66A-61A-6NEW VERIZON WIRELESS 17"x30"(MEET-ME-POINT) IN R.O.W.2'-10"2'-4"NEW FRP2'-4"NEW FRP10'-4"NEW AWNING (TO MATCH EXISTING)EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)PROPERTY LINERIGHT OF WAY"ALPHA " S E C T O R 1 0 5 °"BETA" SECTOR 210°5A-6NEW VERIZON WIRELESS DUALDIPLEXERS, (2) PER SECTOR,TOTAL OF (4)2A-6NEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)1'-0"NEW VERIZON POWER AND FIBERWEATHER HEADS(MIN. 1FT SEPARATION)Item 8.a. - Page 16 NEW & EXISTINGSOUTHEASTELEVATIONS21/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-4NEW SOUTHEAST ELEVATION11/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'SHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALTOP OF NEW VERIZON WIRELESS FRP SCREEN (FAUX AWNING)ELEV. 20' AGLGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLEXISTING SOUTHEAST ELEVATIONEXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 19'-0" AGLRAD CENTER OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 18-0' AGLNEW VERIZON WIRELESSEQUIPMENT AREA(BEHIND, LOCATED ATREAR OF BUILDING)1A-3NEW VERIZON WIRELESS RRUS,(4)TOTAL, MOUNTED TO EXISTINGBUILDING (SHOWN HIDDEN)NEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')NEW VERIZON WIRELESSCONDUIT PENETRATIONS6A-6TOP OF EXISTING PARAPET WALLELEV. 22.9' AGLNEW VERIZON WIRELESS PANELANTENNAS MOUNTED BEHINDNEW FRP SCREEN (FAUXAWNING), (2) TOTAL1A-6EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLBOTTOM OF NEW VERIZON WIRELESSFRP SCREEN (FAUX AWNING)ELEV. 16'-3" AGL5A-6NEW VERIZON WIRELESS DUALDIPLEXERS, (2) PER SECTOR,TOTAL OF (4)2A-6TOP OF EXISTING FACADE PEAKELEV. 26.4' AGLItem 8.a. - Page 17 21/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-5NEW SOUTHWEST ELEVATION11/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'SHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLEXISTING SOUTHWEST ELEVATIONTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLNEW & EXISTINGSOUTHWESTELEVATIONSNEW VERIZON WIRELESS RRUS, (4)TOTAL,MOUNTED EXISTING BUILDING (SHOWNHIDDEN)EXISTING BUILDING IN FOREGROUND(SHOWN AS SECTION THROUGH)GROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLEXISTING ELECTRICAL METERSNEW VERIZONWIRELESSEQUIPMENT CABINETMOUNTED ON NEWCONCRETE PADLOCATED ATGROUND LEVELNEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')NEW VERIZON WIRELESS CONDUITPENETRATIONSEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGNEW VERIZON WIRELESSGPS ANTENNA MOUNTED(ABOVE) ON EXISTINGBUILDING6A-64A-63A-6EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLNEW VERIZON WIRELESS PANEL ANTENNAS MOUNTEDBEHIND NEW FRP SCREEN (FAUX AWNING), (2) TOTAL1A-6EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)TOP OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 19'-0" AGLRAD CENTER OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 18'-0" AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLBOTTOM OF NEW VERIZON WIRELESSFRP SCREEN (FAUX AWNING)ELEV. 16'-3" AGL5A-6TOP OF NEW VERIZON WIRELESS FRP SCREEN (FAUX AWNING)ELEV. 20' AGLEXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLNEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)NEW VERIZON POWER AND FIBERWEATHER HEADS(MIN. 1FT SEPARATION)Item 8.a. - Page 18 DETAILSA-63N.T.S.SCALE2N.T.S.SCALE8N.T.S.SCALE1N.T.S.SCALENOT USEDNOT USED7N.T.S.SCALESHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC11/4/2019 PLANNING SUBMITTAL1 2/20/19 OMREVISED SUBMITTALANTENNA DETAIL5N.T.S.SCALERADIO DETAIL4N.T.S.SCALEEQUIPMENT CABINET DETAILERICCSON 4449DIMENSIONS:HEIGHT: 15"WIDTH: 13.2"DEPTH: 9.3"WEIGHT: 70LBS#2 AWG BTCW(TYP. 3 PLACES)GPS ANTENNA1-1/4"Ø PIPECABLE TO PIPE CONNECTORBURNDY TYPE GARTOP OFPARAPET WALLCONTINUOUS BEAD OFSILICONE SEALANT @TOP OF UNISTRUT, TYP.12" MIN. LENGTHUNISTRUT P1000, TYP.CONDUIT CLAMPNEOPRENE WASHER @THREADED ROD, TYP.#6 AWG GROUNDINGCABLE KIT1/2"Ø COAXIAL CABLESECURE TO WALL USINGHILTI CONCRETE SCREWS,1/4"Ø X 1-3/4" LONGCOPPER ISOLATEDGROUND BUSUNISTRUT HEXHEAD CAPSCREW (TYP)NEW 3-1/2" ODGALVANIZED PIPECOLUMNNEW 1/2" U-BOLT, A307OR BETTERNEW P2800-50 U-SHAPEFITTING (TYP. OF 2 PERU-BOLT)UNISTRUT SPRING NUT(MIN. OF 4 PLACES)1/2" HEX NUT1"Ø x 1/8" WASHERP1000 UNISTRUTCABINET(7) 1.75" / 2.5"KNOCKOUT(BOTH SIDESOF CABINET)CHARLES UNIVERSAL BROADBAND ENCLOSURE (CUBE) SS4C215DB3REGULATORY SPECIFICATIONS:WEIGHT (W/ BATTERIES)RACK MOUNTINGCOLORMATERIAL73"H x 32"W x 32"D 740LBS23" (15RU)OFF WHITE.125" WELDED ALUMINUMMOUNTING STYLEPAD MOUNT ENCLOSUREDOOR LATCHING3-POINT LATCHING WITH PAD LOCKABLE HANDLEBATTERY TYPES / TERMINATIONNi-CD OR VRLA, ANDERSON DISCONNECTS FOR EACH STRINGAC TERMINATION12 POSITION LOAD CENTER (LEFT HAND SIDE)BUS BARSTWO (2) 2X14 POSITION BUS BARS(7) 1.75/2.5" DOUBLE KNOCKOUT ON RHS(7) 1.75/2.5" DOUBLE KNOCKOUT ON LHS(4) 1.75/2.5" DOUBLE KNOCKOUT ON REARCABLE ENTRANCEALARMSDOOR INTRUSION (2)CERTIFICATIONSTELCORDIA ZONE 4 SEISMIC, TELCORDIA GR-487 AND ULDIMENSIONS AND WEIGHT (W/ OUT BATTERIES)1811LBS32.132.132.332.3FRONT VIEWSIDE VIEWPLAN VIEW74.1"72.3"6.9"5.4"3.5"3.2"8.1"14"2.7"LENGTH: 23.2"WIDTH: 12.0"DEPTH: 7.1"WEIGHT: 13 LBSAMPHENOLHTXCWW63111414Fxy012"23.2"7.1"FOR MOUNTING USE:2-POINT MOUNTING &DOWNTILT BRACKETKIT -AMPHENOLPART # 36210006FRONTSIDEGPS DETAILS6N.T.S.SCALEMOUNTING DETAIL9.3"15"FRONTSIDETOP13.2"11.1"15"FRONTSIDETOP13.2"ERICCSON 8843DIMENSIONS:HEIGHT: 15"WIDTH: 13.2"DEPTH: 11.1"WEIGHT: 75LBSRADIO DETAILDIPLEXER SPECIFICATIONSItem 8.a. - Page 19 Minutes:ARC PAGE 3 Monday, May 6, 2019 AYES: Hall, Juette, Berlin, Couch NOES: None ABSENT: Hoag Committee Member Couch excused himself from the meeting at 3:38 p.m. 8. PROJECTS 8.a. CONSIDERATION OF CONDITIONAL USE PERMIT 19-001; NEW SMALL CELL TELECOMMUNICATION FACILITY OF PRIVATE PROPERTY; LOCATION - 119 E. BRANCH STREET; APPLICANT - VERIZON WIRELESS; REPRESENTATIVE - TRICIA KNIGHT (Downing) Planning Manager Downing presented the staff report and gave background about the project site, the City's siting requirements for telecommunication facilities, and the project in relation to the Village Design Guidelines. The Committee spoke in opposition to the location of the equipment behind the proposed awning and, would prefer the equipment to be located behind the parapet, if possible, would prefer a rounded awning that was more complimentary to the building's architecture, and met the requirements of the Village Design Guidelines. Vice Chair Berlin made a motion, seconded by Committee Member Juette, to recommend a continuation of the item to a date uncertain to allow the applicant to be present. The motion passed 3-0 on the following voice vote: AYES: Berlin, Juette, Hall NOES: None ABSENT: Hoag, Couch 9.c. ELECTION OF CHAIR AND VICE CHAIR (Downing) Planning Manager Downing presented the item and Vice Chair Berlin recommended a continuation of the item to the May 20, 2019 Regular Meeting to allow all Committee Members to be present for the election. The recommendation was unanimously supported. 10. COMMITTEE COMMUNICATIONS None. 11. STAFF COMMUNICATIONS Planning Manager Downing formally introduced and welcomed Committee Member Juette to the ARC. 12. ADJOURNMENT The meeting was adjourned at 4:15 p.m.to a regular meeting on May 20, 2019 at 2:30 p.m. NDREW PEREZ ( : ARREN HOAG ASSISTANT PLANNER CHAIR Approved at ARC Meeting 6- 3-19 ) ATTACHMENT 2 Item 8.a. - Page 20 5015 SHOREHAM PLACE, SUITE 150SAN DIEGO, CA 92122www.sacw.comSAC AE DESIGN GROUP, INC.NEWEXISTINGPHOTOSIMULATION VIEWPOINT 1DT ARROYO GRANDE SC1PSL # 285338119 & 121 E. BRANCH STARROYO GRANDE, CA 93420NEW VERIZON WIRELESS PANELANTENNAS WALL MOUNTED TOEXISTING BUILDING AND BEHINDNEW FRP SCREENING (FAUXAWNING) - COLOR AND MATERIALTO MATCH EXISTINGATTACHMENT 3Item 8.a. - Page 21 DT ARROYO GRANDE SC1CONSTRUCTION:RADIO:VERIZON SIGNATURE BLOCKDISCIPLINE:SIGNATURE:DATE:EQUIPMENT:SITE ACQUISITION:MICROWAVE:TELCO:WO ADMINISTRATOR:PROJECT ADMINISTRATOR:CODE COMPLIANCEPSL # 285338119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420DRIVING DIRECTIONSTO: 119 & 121 E. BRANCH ST. ARROYO GRANDE, CA 93420VICINITY MAPFROM: 2785 MITCHELL DR.WALNUT CREEK, CA 94958T-1A-1.1A-4SHEETT-1DESCRIPTIONTITLE SHEETREVPLANNER:CONSTRUCTION:SAC WIRELESS SIGNATURE BLOCKDISCIPLINE:SIGNATURE:SITE ACQUISITION:LANDLORD:NEW & EXISTING SOUTHEAST ELEVATIONCALL 811RCallbefore you dig.below.Know what'sCONTRACTOR TO CALL TOVERIFY UTILITIES ATLEAST TWO WORKINGDAYS PRIOR TO DIGGINGWWW.CALL811.COM SITE PLANDATE:A-3EQUIPMENT & ANTENNA PLANZONING DRAWINGS - NOT FOR CONSTRUCTIONPROJECT SUMMARYPROJECT TEAMSMITHCO SURVEYING ENGINEERINGP.O. BOX 81626BAKERSFIELD, CA 93380CONTACT: GREG SMITH, PLSTELEPHONE: (661) 393-1217ARCHITECT:SURVEYOR:UTILITY COORDINATOR:SAC WIRELESS, LLC.NESTOR POPOWYCH, AIA5015 SHOREHAM PL, SUITE 150SAN DIEGO, CA 92122CONTACT: OMAR MUNOZTELEPHONE: (619) 736-3588PLANNINGSITE ACQUISITIONTITLE SHEETA-5NEW & EXISTING SOUTHWEST ELEVATIONC-1 SITE SURVEYPROPERTY INFORMATION:SITE NAME: DT ARROYO GRANDE SC1SITE NUMBER: 285338SITE ADDRESS: 119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420JURISDICTION: CITY OF ARROYO GRANDEASSESSOR'S PARCEL NUMBERCURRENT ZONING:TYPE OF CONSTRUCTION:AREA OF CONSTRUCTION:HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMANHABITATION. HANDICAPPED ACCESS NOT REQUIRED.V-B007-192-056 AND 007-192-057GEODETIC COORDINATESLAT.LONG.ELEVATION.VILLAGE CORE DOWNTOWNCONSTRUCTION INFORMATION35° 07' 25.48"120° 34' 41.98"126.4' NAVD 88(BASIS OF DRAWING)OCCUPANCY:UAPPLICANT/LESSEE2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598OFFICE: (925) 279-6000APPLICANT'S REPRESENTATIVE1. HEAD NORTHEAST ON MITCHELL DR TOWARD OAK GROVE RD2. TURN RIGHT ONTO OAK GROVE RD3. TURN RIGHT ONTO YGNACIO VALLEY RD4. YGNACIO VALLEY RD TURNS RIGHT AND BECOMES HILLSIDE AVE5. USE THE LEFT 2 LANES TO TURN LEFT ONTO THE INTERSTATE 680 S RAMP TO SAN JOSE6. MERGE ONTO I-680 S7. TAKE THE ANDRADE RD EXIT TOWARD SHERIDAN RD8. CONTINUE ONTO MISSION RD9. MERGE ONTO I-680 S VIA THE RAMP TO FREMONT/SAN JOSE10. USE THE RIGHT 3 LANES TO MERGE ONTO US-101 S TOWARD LOS ANGELES11. CONTINUE STRAIGHT TO STAY ON US-101 S12. TAKE EXIT 187A FOR CA-227/GRAND AVE13. TURN LEFT ONTO CA-227 N/E GRAND AVETEK CONSULTING INC.PERMIT PROCESSING SERVICES123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221FAX: (805) 888-2807TEK-CONSULTING.NETC-2 SITE SURVEYSAC WIRELESS1057 LA VISTA ROADSANTA BARBARA, CA 93110CONTACT: CRAIG ENGELTELEPHONE: (805) 440-0038TEK CONSULTING INC.123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221TEK-CONSULTING.NETGENERAL CONTRACTOR NOTESDO NOT SCALE DRAWINGS IF NOT FULL SIZE (24 X 36)CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ONTHE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANYDISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THESAME.PROJECT DESCRIPTIONTHIS PROJECT IS A VERIZON UNMANNED TELECOMMUNICATION WIRELESSFACILITY. IT WILL CONSIST OF THE FOLLOWING:x(2) NEW ANTENNASx(4) NEW RRU'Sx(4) NEW DUAL DIPLEXERSx(1) NEW EQUIPMENT CABINETx(1) NEW GPS ANTENNAxNEW FRP SCREEN / FAUX AWNINGxNEW ELECTRICAL METERPROPERTY OWNER:OWNER: ADNAN EL-HELOUADDRESS: 224 CHRISTINE WAYPISMO BEACH, CA 93449CONTACT: ADNAN EL-HELOUTELEPHONE: 805-801-7464EMAIL: aelhelou@sbcglobal.netSITENOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSA-2ENLARGED ROOF PLAN088NORTHSAC WIRELESS, LLC.8880 CAL CENTER DRIVESUITE 130SACRAMENTO, CA 95826CONTACT: JOSEPH SHARPTELEPHONE: (916) 205-9305JOSEPH.SHARP@SACW.COMA-6DETAILSx2016 CALIFORNIA ADMINISTRATIVE CODEx2016 CALIFORNIA BUILDING CODESx2016 CALIFORNIA ELECTRICAL CODEx2016 CALIFORNIA FIRE CODEx2016 CALIFORNIA ENERGY CODExCITY & COUNTY ORDINANCES001110A-1500FT RADIUS MAP0C-3 SITE SURVEY8ATTACHMENT 4Item 8.a. - Page 22 Item 8.a. - Page 23 Item 8.a. - Page 24 Item 8.a. - Page 25 500FT RADIUS MAP500FT RADIUS MAP1" = 50'-0" (24x36)(OR)SCALE:1/2" = 50'-0" (11x17)50'25' 50'0A-11NORTHNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSVERIZON SITERADIUS= 500FTItem 8.a. - Page 26 90 90 SITE PLANSITE PLAN1/2" = 20'-0" (11x17)SCALE:(OR)1" = 20'-0" (24x36)20' 10' 20'0A-1.11NORTHNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSCL1A-2NEW VERIZON WIRELESSANTENNA & EQUIPMENT AREA,SEE ENLARGED ROOF PLAN"ALPHA" SECTOR 105°"BETA" SECTOR 210°E. BRANCH STREETC LNEVAD A S T R E E TCLLE POINT STREETAPN:007-192-007APN:007-192-008APN:007-192-009APN:007-192-010APN:007-192-067APN:007-192-066APN:007-192-062OWNER: CITY OFARROYO GRANDEAPN:007-192-056APN:007-192-057EXISTING UTILITY POLE #37(NEW VERIZON POWER/FIBER P.O.C.)EXISTING OVERHEADPOWER LINEEXISTING UTILITYPOLENOTE:POWER PLAN: PG&E DESIGN TO BEDETERMINEDTRANSPORT SOLUTION: DESIGN TO BEDETERMINEDLESSEE PROPOSED 12'-0"WIDE ACCESS EASEMENTRIGHT-OF- WAYPROPERTY LINERIGHT OF WAYNEW VERIZON POWER/FIBEROVERHEAD LINES (LENGTH=±100FT)Item 8.a. - Page 27 90 90 ENLARGEDROOF PLANENLARGED ROOF PLAN1/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-21NORTHNEW VERIZON WIRELESSEQUIPMENT AREANOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTS1A-31A-51A-4NOTE:POWER PLAN: PG&E DESIGN TO BEDETERMINEDTRANSPORT SOLUTION: DESIGN TO BEDETERMINEDNEW VERIZON WIRELESSANTENNA AREA2A-3NEW VERIZONWIRELESS FIBER,DC POWER &GROUNDCONDUITS ONSLEEPERS(APPROX. 100')EXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056APN:007-192-057EXISTING RETAININGWALLACUNITACUNITACUNITROOFACCESSHATCHEXISTING 1/2" DIA.CONDUITPROP E R T Y LI N E PROPERTY LINEPROP E R T Y LI N E 2A-52A-4EXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGPROPERTY LINERIGHT OF WAYLESSEE PROPOSED 12'-0"WIDE ACCESS EASEMENTRIGHT-OF- WAYAPN:007-192-055APN:007-192-062OWNER: CITY OFARROYO GRANDE"BETA" SECTOR 210°NEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)"ALPHA" SECTOR 105°Item 8.a. - Page 28 EQUIPMENT &ANTENNA PLANANTENNA PLAN1/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)06"1' 2'2A-3NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSEQUIPMENT PLAN1/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)06"1' 2'1NEW VERIZON WIRELESS EQUIPMENTCABINET MOUNTED ON NEW CONCRETEPAD LOCATED AT GROUND LEVELNEW VERIZON WIRELESS RRUS,(4)TOTAL, MOUNTED TO EXISTINGBUILDING WITHIN NEW ENCLOSURES(NO TOP OR BOTTOM ENCLOSUREFOR VENTILATION PURPOSES)NORTHNEW VERIZON WIRELESS PANELANTENNAS MOUNTED BEHIND NEW FRPSCREEN (FAUX AWNING), (2) TOTALNORTH15'-2"NEW VERIZON WIRELESS FRP SCREENING (NEW FAUX AWNING)NEW VERIZON WIRELESS LEASE AREANEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')EXISTING 1/2" DIA. CONDUITEXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056APN:007-192-057EXISTING ROOFACCESS HATCHEXISTING AC UNITEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056EXISTINGBUILDINGROOFTOPAPN:007-192-057EXISTINGGROUNDLEVEL3'-4"NEWVERIZON WIRELESSLEASE AREA3'-7"NEWVERIZON WIRELESSLEASE AREA3'-4"EXISTING ELECTRICAL METERNEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINENEW VERIZON WIRELESS METERPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINENEW VERIZON WIRELESS CONDUIT PENETRATIONSNEW VERIZONWIRELESS 17x30FIBER PULL BOXNEW VERIZON WIRELESS 4" FIBER CONDUITROUTE TO NEW EQUIPMENT CABINETNEW VERIZON WIRELESS GPSANTENNA MOUNTED (ABOVE)ON EXISTING BUILDINGEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGEXISTING WEATHER HEAD (ABOVE)MOUNTED TO EXISTING BUILDINGEXISTING RETAINING WALL4A-63A-66A-61A-62'-10"4'-2"NEW FRP4'-2"NEW FRP6'-10"NEW AWNING (TO MATCH EXISTING)EXISTING AWNING, (3) TOTALTO BE REMOVED(SHOWN HIDDEN)PROPERTY LINERIGHT OF WAY"ALPHA" S E C T O R 1 0 5 °"BETA" SECTOR 210°5A-6NEW VERIZON WIRELESS DUALDIPLEXERS, (2) PER SECTOR,TOTAL OF (4)2A-6NEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)1'-0"NEW VERIZON POWER AND FIBERWEATHER HEADS(MIN. 1FT SEPARATION)Item 8.a. - Page 29 NEW & EXISTINGSOUTHEASTELEVATIONS21/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-4NEW SOUTHEAST ELEVATION11/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSTOP OF NEW VERIZON WIRELESS FRP SCREEN (FAUX AWNING)ELEV. 20' AGLGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLEXISTING SOUTHEAST ELEVATIONEXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 19'-10" AGLRAD CENTER OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 18'-10" AGLNEW VERIZON WIRELESSEQUIPMENT AREA(BEHIND, LOCATED ATREAR OF BUILDING)1A-3NEW VERIZON WIRELESS RRUS,(4)TOTAL, MOUNTED TO EXISTINGBUILDING (SHOWN HIDDEN)NEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')NEW VERIZON WIRELESSCONDUIT PENETRATIONS6A-6TOP OF EXISTING PARAPET WALLELEV. 22.9' AGLNEW VERIZON WIRELESS PANELANTENNAS MOUNTED BEHINDNEW FRP SCREEN (FAUXAWNING), (2) TOTAL1A-6EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLBOTTOM OF NEW VERIZON WIRELESSFRP SCREEN (FAUX AWNING)ELEV. 17'-0" AGL5A-6NEW VERIZON WIRELESS DUALDIPLEXERS, (2) PER SECTOR,TOTAL OF (4)2A-6TOP OF EXISTING FACADE PEAKELEV. 26.4' AGLItem 8.a. - Page 30 21/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-5NEW SOUTHWEST ELEVATION11/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLEXISTING SOUTHWEST ELEVATIONTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLNEW & EXISTINGSOUTHWESTELEVATIONSNEW VERIZON WIRELESS RRUS, (4)TOTAL,MOUNTED EXISTING BUILDING (SHOWNHIDDEN)EXISTING BUILDING IN FOREGROUND(SHOWN AS SECTION THROUGH)GROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLEXISTING ELECTRICAL METERSNEW VERIZONWIRELESSEQUIPMENT CABINETMOUNTED ON NEWCONCRETE PADLOCATED ATGROUND LEVELNEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')NEW VERIZON WIRELESS CONDUITPENETRATIONSEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGNEW VERIZON WIRELESSGPS ANTENNA MOUNTED(ABOVE) ON EXISTINGBUILDING6A-64A-63A-6EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLNEW VERIZON WIRELESS PANEL ANTENNAS MOUNTEDBEHIND NEW FRP SCREEN (FAUX AWNING), (2) TOTAL1A-6EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)TOP OF EXISTING PARAPET WALLELEV. 22.9' AGL5A-6TOP OF NEW VERIZON WIRELESS FRP SCREEN (FAUX AWNING)ELEV. 20' AGLEXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLNEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)NEW VERIZON POWER AND FIBERWEATHER HEADS(MIN. 1FT SEPARATION)TOP OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 19'-10" AGLRAD CENTER OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 18'-10" AGLBOTTOM OF NEW VERIZON WIRELESS ANTENNASELEV. 17'-0" AGL1'-4"Item 8.a. - Page 31 DETAILSA-63N.T.S.SCALE2N.T.S.SCALE8N.T.S.SCALE1N.T.S.SCALENOT USEDNOT USED7N.T.S.SCALENOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSANTENNA DETAIL5N.T.S.SCALERADIO DETAIL4N.T.S.SCALEEQUIPMENT CABINET DETAILERICCSON 4449DIMENSIONS:HEIGHT: 15"WIDTH: 13.2"DEPTH: 9.3"WEIGHT: 70LBS#2 AWG BTCW(TYP. 3 PLACES)GPS ANTENNA1-1/4"Ø PIPECABLE TO PIPE CONNECTORBURNDY TYPE GARTOP OFPARAPET WALLCONTINUOUS BEAD OFSILICONE SEALANT @TOP OF UNISTRUT, TYP.12" MIN. LENGTHUNISTRUT P1000, TYP.CONDUIT CLAMPNEOPRENE WASHER @THREADED ROD, TYP.#6 AWG GROUNDINGCABLE KIT1/2"Ø COAXIAL CABLESECURE TO WALL USINGHILTI CONCRETE SCREWS,1/4"Ø X 1-3/4" LONGCOPPER ISOLATEDGROUND BUSUNISTRUT HEXHEAD CAPSCREW (TYP)NEW 3-1/2" ODGALVANIZED PIPECOLUMNNEW 1/2" U-BOLT, A307OR BETTERNEW P2800-50 U-SHAPEFITTING (TYP. OF 2 PERU-BOLT)UNISTRUT SPRING NUT(MIN. OF 4 PLACES)1/2" HEX NUT1"Ø x 1/8" WASHERP1000 UNISTRUTCABINET(7) 1.75" / 2.5"KNOCKOUT(BOTH SIDESOF CABINET)CHARLES UNIVERSAL BROADBAND ENCLOSURE (CUBE) SS4C215DB3REGULATORY SPECIFICATIONS:WEIGHT (W/ BATTERIES)RACK MOUNTINGCOLORMATERIAL73"H x 32"W x 32"D 740LBS23" (15RU)OFF WHITE.125" WELDED ALUMINUMMOUNTING STYLEPAD MOUNT ENCLOSUREDOOR LATCHING3-POINT LATCHING WITH PAD LOCKABLE HANDLEBATTERY TYPES / TERMINATION Ni-CD OR VRLA, ANDERSON DISCONNECTS FOR EACH STRINGAC TERMINATION12 POSITION LOAD CENTER (LEFT HAND SIDE)BUS BARSTWO (2) 2X14 POSITION BUS BARS(7) 1.75/2.5" DOUBLE KNOCKOUT ON RHS(7) 1.75/2.5" DOUBLE KNOCKOUT ON LHS(4) 1.75/2.5" DOUBLE KNOCKOUT ON REARCABLE ENTRANCEALARMSDOOR INTRUSION (2)CERTIFICATIONSTELCORDIA ZONE 4 SEISMIC, TELCORDIA GR-487 AND ULDIMENSIONS AND WEIGHT (W/ OUT BATTERIES)1811LBS32.132.132.332.3FRONT VIEWSIDE VIEWPLAN VIEW74.1"72.3"6.9"5.4"3.5"3.2"8.1"14"2.7"LENGTH: 23.2"WIDTH: 12.0"DEPTH: 7.1"WEIGHT: 13 LBSAMPHENOLHTXCWW63111414Fxy012"23.2"7.1"FOR MOUNTING USE:2-POINT MOUNTING &DOWNTILT BRACKETKIT -AMPHENOLPART # 36210006FRONTSIDEGPS DETAILS6N.T.S.SCALEMOUNTING DETAIL9.3"15"FRONTSIDETOP13.2"11.1"15"FRONTSIDETOP13.2"ERICCSON 8843DIMENSIONS:HEIGHT: 15"WIDTH: 13.2"DEPTH: 11.1"WEIGHT: 75LBSRADIO DETAILDIPLEXER SPECIFICATIONSItem 8.a. - Page 32