Loading...
ARC 2019-08-05_08a Verizon Village CUP MEMORANDUM TO: ARCHITECTURAL REVIEW COMMITTEE FROM: MATTHEW DOWNING, PLANNING MANAGER SUBJECT: CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19- 001; NEW SMALL CELL TELECOMMUNICATION FACILITY ON PRIVATE PROPERTY; LOCATION – 119 E. BRANCH STREET; APPLICANT – VERIZON WIRELESS; REPRESENTATIVE – TRICIA KNIGHT DATE: AUGUST 5, 2019 SUMMARY OF ACTION: Approval of the project would allow a small cell telecommunication facility to be installed on private property in the Village. IMPACT ON FINANCIAL AND PERSONNEL RESOURCES: None. RECOMMENDATION: It is recommended that the Architectural Review Committee (ARC) review the proposed project and make a recommendation for approval to the Planning Commission. BACKGROUND: The ARC reviewed the proposed project most recently on June 17, 2019 (Attachments 1 & 2). At that time, the applicant’s representative requested feedback on how the project was addressing the ARC’s previous concerns and preferences for the project, which were: 1. A preference to locate all of the small cell equipment behind the building’s parapet; 2. If an awning remains proposed, the awning should be striped to better match the first floor awning; 3. A preference for an awning design that reflected the window arches, as they are a unique feature of the building; and 4. A loose, scalloped valance needs to be included with an awning. At the June meeting, it was determined that placing equipment behind the building’s parapet was not feasible and that awning screening was the preferred option. However, at the time, the project was intended to utilize fiberglass materials to simulate traditional canvas awning material. Due to concerns regarding the aesthetics of the fiberglass materials, the applicant’s representative requested additional time to investigate the use of more traditional canvas on the awning instead of fiberglass. The applicant’s Item 8.a. - Page 1 ARCHITECTURAL REVIEW COMMITTEE CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19-001 AUGUST 5, 2019 PAGE 2 representative has informed staff that a more traditional canvas awning material will adequately transmit signals from the small cell. ANALYSIS OF ISSUES: The updated proposal remains a three-arched awning that will follow the existing arches of the building, utilizing the striped appearance with loose, black valance as previously proposed. A sample of the material will be available at the meeting. It is being referenced as an awning-type structure as the structure is largely made of fiberglass painted to match the cloth awnings on the lower floor. The wireless panel antennas remain located under the awning as previously proposed while the awning frame will be constructed of fiberglass. Based on the revised materials proposed, the project complies with the Design Guidelines and is consistent with previous ARC feedback. ADVANTAGES: The proposed project will increase cellular data capacity in the vicinity of the Village, allowing the applicant to continue to serve its customers as they have come to expect. The new awning will also replace a dilapidated awning in the same location. DISADVANTAGES: None. ENVIRONMENTAL REVIEW: The project has been reviewed in compliance with the California Environmental Quality Act (CEQA), the State CEQA Guidelines, and has been determined to be categorically exempt pursuant to Sections 15301(e)(2), 15303(c), and 15332 of the CEQA Guidelines regarding existing facilities, new construction, and in-fill development projects in urban areas. PUBLIC NOTIFICATION AND COMMENT: The Agenda was posted at City Hall and on the City’s website in accordance with Government Code Section 54954.2. No comments have been received regarding the proposed project. Attachments: 1. June 17, 2019 staff report (less attachments) 2. Minutes from the June 17, 2019 Architectural Review Committee meeting 3. Revised photo simulations (previously distributed) 4. Revised project plans (previously distributed) Item 8.a. - Page 2 MEMORANDUM TO: ARCHITECTURAL REVIEW COMMITTEE FROM: MATTHEW DOWNING, PLANNING MANAGER SUBJECT: CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19- 001; NEW SMALL CELL TELECOMMUNICATION FACILITY ON PRIVATE PROPERTY; LOCATION – 119 E. BRANCH STREET; APPLICANT – VERIZON WIRELESS; REPRESENTATIVE – TRICIA KNIGHT DAT E: JUNE 17, 2019 SUMMARY OF ACTION: Approval of the project would allow a small cell telecommunication facility to be installed on private property in the Village. IMPACT ON FINANCIAL AND PERSONNEL RESOURCES: None. RECOMMENDATION: It is recommended that the Architectural Review Committee (ARC) review the proposed project and make a recommendation for approval to the Planning Commission. BACKGROUND: The ARC reviewed the proposed project on May 6, 2019 (Attachments 1 & 2). At that time, members of the ARC were hesitant to make a recommendation on the application due to questions and concerns arising from the proposal and the unavailability of a project representative to respond to the concerns. Specifically, these concerns and preferences were: 1.A preference to locate all of the small cell equipment behind the building’s parapet; 2.If an awning remains proposed, the awning should be striped to better match the first floor awning; 3.A preference for an awning design that reflected the window arches, as they are a unique feature of the building; and 4.A loose, scalloped valance needs to be included with an awning. These items were provided to the applicant’s representative and the project has been revised to address these items. ATTACHMENT 1 Item 8.a. - Page 3 ARCHITECTURAL REVIEW COMMITTEE CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19-001 JUNE 17, 2019 PAGE 2 ANALYSIS OF ISSUES: The updated proposal includes a three-arched awning-type structure that will follow the existing arches of the building. It is being referenced as an awning-type structure as the structure is largely made of fiberglass painted to match the cloth awnings on the lower floor. The proposal also includes a loose, black valance that will be made of cloth and include the “Skin Care Clinic” copy from the previous awning. The wireless panel antennas remain located under the awning as previously proposed. The Design Guidelines identify that awnings should be compatible in color and design with that of the building. Based on the previous feedback from the ARC, the revised awning design and color achieve the compatibility directed by the Design Guidelines. However, the clarification that the awning is necessary to be fiberglass is not consistent with the Design Guidelines, which specifically say that “Aluminum, fiberglass and plastic awnings or canopies are not appropriate (see Page 38). ADV ANTAGES: The proposed project will increase cellular data capacity in the vicinity of the Village, allowing the applicant to continue to serve its customers as they have come to expect. The new awning will also replace a dilapidated awning in the same location. DISADVANTAGES: The use of fiberglass as the primary awning material is not consistent with the Design Guidelines. ENVIRONMENTAL REVIEW: The project has been reviewed in compliance with the California Environmental Quality Act (CEQA), the State CEQA Guidelines, and has been determined to be categorically exempt pursuant to Sections 15301(e)(2), 15303(c), and 15332 of the CEQA Guidelines regarding existing facilities, new construction, and in-fill development projects in urban areas. PUBLIC NOTIFICATION AND COMMENT: The Agenda was posted at City Hall and on the City’s website in accordance with Government Code Section 54954.2. No comments have been received regarding the proposed project. Attachments: 1.May 6, 2019 staff report 2.Minutes from the May 6, 2019 Architectural Review Committee meeting 3.Revised photo simulations 4.Revised project plans Item 8.a. - Page 4 ACTION MINUTES REGULAR MEETING OF THE ARCHITECTURAL REVIEW COMMITTEE MONDAY, JUNE 17, 2019 ARROYO GRANDE CITY HALL, 300 E. BRANCH STREET ARROYO GRANDE, CA 1.CALL TO ORDER Chair Hoag called the Regular Architectural Review Committee meeting to order at 2:30 p.m. 2.ROLL CALL ARC Members:Chair Warren Hoag, Vice Chair Bruce Berlin and Committee Members Jon Couch, and Kristin Juette were present. Committee Member Lori Hall was absent. City Staff Present: Planning Manager Matt Downing and Assistant Planner Andrew Perez were present. 3.FLAG SALUTE Committee Member Juette led the Flag Salute. 4.AGENDA REVIEW None. 5.COMMUNITY COMMENTS AND SUGGESTIONS None. 6.WRITTEN COMMUNICATIONS None. 7.CONSENT AGENDA Vice Chair Berlin made a motion, seconded by Committee Member Juette, to approve the minutes of the June 3, 2019, Regular Meeting. The motion passed 4-0 on the following voice vote: AYES: Berlin, Juette, Couch, Hoag NOES: None ABSENT: Hall 8.PROJECTS 8.a. CONTINUED CONSIDERATION OF CONDITIONAL USE PERMIT 19-001; NEW SMALL CELL TELECOMMUNICATION FACILITY ON PRIVATE PROPERTY; LOCATION – 119 E. BRANCH STREET; APPLICANT – VERIZON WIRELESS; REPRESENTATIVE – TRICIA KNIGHT (Downing) Planning Manager Downing presented the staff report and summarized the comments from the Committee’s previous review of the project at the May 6, 2019, Regular Meeting. Planning Manager Downing explained the revisions made to the project to address the Committee’s previous concerns through the proposal of a new, fiberglass awning to shelter the telecommunication equipment, which would be painted to match the first floor awning and would include a loose, scalloped valance. ATTACHMENT 2 Item 8.a. - Page 5 Minutes: ARC PAGE 2 Monday, June 17, 2019 Tricia Knight, project representative, provided some clarification why fiberglass was chosen for the awning instead of a customary fabric awning, explained why this location was chosen and explained the drawbacks to installing the equipment within the existing building façade. The Committee spoke in support of the direction the project is headed from an aesthetic perspective, and appreciated the aesthetic treatment of the awning with the striping to match the first floor awning. The Committee was not supportive of the fiberglass because it does not comply with the Village Design Guidelines, is likely to be much more rigid than a traditional fabric awning, and will likely have a reflective quality that could be a detriment to The Village’s aesthetics. The Committee was also concerned that a material sample of the fiberglass was not provided. Chair Hoag recommended a continuation of the item until the applicant can provide a material sample, and additional information about how the awning and telecommunication will be attached to the building. The recommendation was unanimously supported by the Committee. 9. DISCUSSION ITEMS None 10. COMMITTEE COMMUNICATIONS Committee Member Couch announced that he will be absent from the July 1, 2019, Regular Meeting. Chair Hoag announced that he will be absent from the July 15, 2019, Regular Meeting. Committee Member Couch relayed a compliment from staff at Ten Over Studios to the Committee that they appreciated the constructive feedback and overall positivity they received at the May 20, 2019, Regular Meeting. 11. STAFF COMMUNICATIONS Planning Manager Downing appreciated the Committee’s flexibility and feedback on Item 8.a. Planning Manager Downing announced that the Housing Element Update scope of work is being reviewed by the Planning Commission at their June 18, 2019 meeting. Planning Manager Downing announced that the public improvements for the Rugged Radio project in Subarea 1 of the East Cherry Specific Plan should begin in the near future. 12. ADJOURNMENT The meeting was adjourned at 3:12 p.m.to a regular meeting on July 1, 2019 at 2:30 p.m. _____________________________ _____________________________ ANDREW PEREZ WARREN HOAG ASSISTANT PLANNER CHAIR (Approved at ARC Meeting 07-15-2019) Item 8.a. - Page 6 5015 SHOREHAM PLACE, SUITE 150SAN DIEGO, CA 92122www.sacw.comSAC AE DESIGN GROUP, INC.NEWEXISTINGPHOTOSIMULATION VIEWPOINT 1DT ARROYO GRANDE SC1PSL # 285338119 & 121 E. BRANCH STARROYO GRANDE, CA 93420NEW VERIZON WIRELESS PANELANTENNAS WALL MOUNTED TOEXISTING BUILDING AND BEHINDNEW FRP SCREENING (FAUXAWNING) - COLOR AND MATERIALTO MATCH EXISTINGATTACHMENT 3Item 8.a. - Page 7 DT ARROYO GRANDE SC1CONSTRUCTION:RADIO:VERIZON SIGNATURE BLOCKDISCIPLINE:SIGNATURE:DATE:EQUIPMENT:SITE ACQUISITION:MICROWAVE:TELCO:WO ADMINISTRATOR:PROJECT ADMINISTRATOR:CODE COMPLIANCEPSL # 285338119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420DRIVING DIRECTIONSTO: 119 & 121 E. BRANCH ST. ARROYO GRANDE, CA 93420VICINITY MAPFROM: 2785 MITCHELL DR.WALNUT CREEK, CA 94958T-1A-1.1A-4SHEETT-1DESCRIPTIONTITLE SHEETREVPLANNER:CONSTRUCTION:SAC WIRELESS SIGNATURE BLOCKDISCIPLINE:SIGNATURE:SITE ACQUISITION:LANDLORD:NEW & EXISTING SOUTHEAST ELEVATIONCALL 811RCallbefore you dig.below.Know what'sCONTRACTOR TO CALL TOVERIFY UTILITIES ATLEAST TWO WORKINGDAYS PRIOR TO DIGGINGWWW.CALL811.COM SITE PLANDATE:A-3EQUIPMENT & ANTENNA PLANZONING DRAWINGS - NOT FOR CONSTRUCTIONPROJECT SUMMARYPROJECT TEAMSMITHCO SURVEYING ENGINEERINGP.O. BOX 81626BAKERSFIELD, CA 93380CONTACT: GREG SMITH, PLSTELEPHONE: (661) 393-1217ARCHITECT:SURVEYOR:UTILITY COORDINATOR:SAC WIRELESS, LLC.NESTOR POPOWYCH, AIA5015 SHOREHAM PL, SUITE 150SAN DIEGO, CA 92122CONTACT: OMAR MUNOZTELEPHONE: (619) 736-3588PLANNINGSITE ACQUISITIONTITLE SHEETA-5NEW & EXISTING SOUTHWEST ELEVATIONC-1 SITE SURVEYPROPERTY INFORMATION:SITE NAME: DT ARROYO GRANDE SC1SITE NUMBER: 285338SITE ADDRESS: 119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420JURISDICTION: CITY OF ARROYO GRANDEASSESSOR'S PARCEL NUMBERCURRENT ZONING:TYPE OF CONSTRUCTION:AREA OF CONSTRUCTION:HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMANHABITATION. HANDICAPPED ACCESS NOT REQUIRED.V-B007-192-056 AND 007-192-057GEODETIC COORDINATESLAT.LONG.ELEVATION.VILLAGE CORE DOWNTOWNCONSTRUCTION INFORMATION35° 07' 25.48"120° 34' 41.98"126.4' NAVD 88(BASIS OF DRAWING)OCCUPANCY:UAPPLICANT/LESSEE2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598OFFICE: (925) 279-6000APPLICANT'S REPRESENTATIVE1. HEAD NORTHEAST ON MITCHELL DR TOWARD OAK GROVE RD2. TURN RIGHT ONTO OAK GROVE RD3. TURN RIGHT ONTO YGNACIO VALLEY RD4. YGNACIO VALLEY RD TURNS RIGHT AND BECOMES HILLSIDE AVE5. USE THE LEFT 2 LANES TO TURN LEFT ONTO THE INTERSTATE 680 S RAMP TO SAN JOSE6. MERGE ONTO I-680 S7. TAKE THE ANDRADE RD EXIT TOWARD SHERIDAN RD8. CONTINUE ONTO MISSION RD9. MERGE ONTO I-680 S VIA THE RAMP TO FREMONT/SAN JOSE10. USE THE RIGHT 3 LANES TO MERGE ONTO US-101 S TOWARD LOS ANGELES11. CONTINUE STRAIGHT TO STAY ON US-101 S12. TAKE EXIT 187A FOR CA-227/GRAND AVE13. TURN LEFT ONTO CA-227 N/E GRAND AVETEK CONSULTING INC.PERMIT PROCESSING SERVICES123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221FAX: (805) 888-2807TEK-CONSULTING.NETC-2 SITE SURVEYSAC WIRELESS1057 LA VISTA ROADSANTA BARBARA, CA 93110CONTACT: CRAIG ENGELTELEPHONE: (805) 440-0038TEK CONSULTING INC.123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221TEK-CONSULTING.NETGENERAL CONTRACTOR NOTESDO NOT SCALE DRAWINGS IF NOT FULL SIZE (24 X 36)CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ONTHE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANYDISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THESAME.PROJECT DESCRIPTIONTHIS PROJECT IS A VERIZON UNMANNED TELECOMMUNICATION WIRELESSFACILITY. IT WILL CONSIST OF THE FOLLOWING:x(2) NEW ANTENNASx(4) NEW RRU'Sx(4) NEW DUAL DIPLEXERSx(1) NEW EQUIPMENT CABINETx(1) NEW GPS ANTENNAxNEW FRP SCREEN / FAUX AWNINGxNEW ELECTRICAL METERPROPERTY OWNER:OWNER: ADNAN EL-HELOUADDRESS: 224 CHRISTINE WAYPISMO BEACH, CA 93449CONTACT: ADNAN EL-HELOUTELEPHONE: 805-801-7464EMAIL: aelhelou@sbcglobal.netSITENOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSA-2ENLARGED ROOF PLAN088NORTHSAC WIRELESS, LLC.8880 CAL CENTER DRIVESUITE 130SACRAMENTO, CA 95826CONTACT: JOSEPH SHARPTELEPHONE: (916) 205-9305JOSEPH.SHARP@SACW.COMA-6DETAILSx2016 CALIFORNIA ADMINISTRATIVE CODEx2016 CALIFORNIA BUILDING CODESx2016 CALIFORNIA ELECTRICAL CODEx2016 CALIFORNIA FIRE CODEx2016 CALIFORNIA ENERGY CODExCITY & COUNTY ORDINANCES001110A-1500FT RADIUS MAP0C-3 SITE SURVEY8ATTACHMENT 4Item 8.a. - Page 8 Item 8.a. - Page 9 Item 8.a. - Page 10 Item 8.a. - Page 11 500FT RADIUS MAP500FT RADIUS MAP1" = 50'-0" (24x36)(OR)SCALE:1/2" = 50'-0" (11x17)50'25' 50'0A-11NORTHNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSVERIZON SITERADIUS= 500FTItem 8.a. - Page 12 90 90 SITE PLANSITE PLAN1/2" = 20'-0" (11x17)SCALE:(OR)1" = 20'-0" (24x36)20' 10' 20'0A-1.11NORTHNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSCL1A-2NEW VERIZON WIRELESSANTENNA & EQUIPMENT AREA,SEE ENLARGED ROOF PLAN"ALPHA" SECTOR 105°"BETA" SECTOR 210°E. BRANCH STREETC LNEVAD A S T R E E TCLLE POINT STREETAPN:007-192-007APN:007-192-008APN:007-192-009APN:007-192-010APN:007-192-067APN:007-192-066APN:007-192-062OWNER: CITY OFARROYO GRANDEAPN:007-192-056APN:007-192-057EXISTING UTILITY POLE #37(NEW VERIZON POWER/FIBER P.O.C.)EXISTING OVERHEADPOWER LINEEXISTING UTILITYPOLENOTE:POWER PLAN: PG&E DESIGN TO BEDETERMINEDTRANSPORT SOLUTION: DESIGN TO BEDETERMINEDLESSEE PROPOSED 12'-0"WIDE ACCESS EASEMENTRIGHT-OF- WAYPROPERTY LINERIGHT OF WAYNEW VERIZON POWER/FIBEROVERHEAD LINES (LENGTH=±100FT)Item 8.a. - Page 13 90 90 ENLARGEDROOF PLANENLARGED ROOF PLAN1/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-21NORTHNEW VERIZON WIRELESSEQUIPMENT AREANOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTS1A-31A-51A-4NOTE:POWER PLAN: PG&E DESIGN TO BEDETERMINEDTRANSPORT SOLUTION: DESIGN TO BEDETERMINEDNEW VERIZON WIRELESSANTENNA AREA2A-3NEW VERIZONWIRELESS FIBER,DC POWER &GROUNDCONDUITS ONSLEEPERS(APPROX. 100')EXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056APN:007-192-057EXISTING RETAININGWALLACUNITACUNITACUNITROOFACCESSHATCHEXISTING 1/2" DIA.CONDUITPROP E R T Y LI N E PROPERTY LINEPROP E R T Y LI N E 2A-52A-4EXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGPROPERTY LINERIGHT OF WAYLESSEE PROPOSED 12'-0"WIDE ACCESS EASEMENTRIGHT-OF- WAYAPN:007-192-055APN:007-192-062OWNER: CITY OFARROYO GRANDE"BETA" SECTOR 210°NEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)"ALPHA" SECTOR 105°Item 8.a. - Page 14 EQUIPMENT &ANTENNA PLANANTENNA PLAN1/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)06"1' 2'2A-3NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSEQUIPMENT PLAN1/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)06"1' 2'1NEW VERIZON WIRELESS EQUIPMENTCABINET MOUNTED ON NEW CONCRETEPAD LOCATED AT GROUND LEVELNEW VERIZON WIRELESS RRUS,(4)TOTAL, MOUNTED TO EXISTINGBUILDING WITHIN NEW ENCLOSURES(NO TOP OR BOTTOM ENCLOSUREFOR VENTILATION PURPOSES)NORTHNEW VERIZON WIRELESS PANELANTENNAS MOUNTED BEHIND NEW FRPSCREEN (FAUX AWNING), (2) TOTALNORTH15'-2"NEW VERIZON WIRELESS FRP SCREENING (NEW FAUX AWNING)NEW VERIZON WIRELESS LEASE AREANEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')EXISTING 1/2" DIA. CONDUITEXISTINGBUILDINGROOFTOPEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056APN:007-192-057EXISTING ROOFACCESS HATCHEXISTING AC UNITEXISTINGBUILDINGROOFTOP(LOWER)APN:007-192-056EXISTINGBUILDINGROOFTOPAPN:007-192-057EXISTINGGROUNDLEVEL3'-4"NEWVERIZON WIRELESSLEASE AREA3'-7"NEWVERIZON WIRELESSLEASE AREA3'-4"EXISTING ELECTRICAL METERNEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINENEW VERIZON WIRELESS METERPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINENEW VERIZON WIRELESS CONDUIT PENETRATIONSNEW VERIZONWIRELESS 17x30FIBER PULL BOXNEW VERIZON WIRELESS 4" FIBER CONDUITROUTE TO NEW EQUIPMENT CABINETNEW VERIZON WIRELESS GPSANTENNA MOUNTED (ABOVE)ON EXISTING BUILDINGEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGEXISTING WEATHER HEAD (ABOVE)MOUNTED TO EXISTING BUILDINGEXISTING RETAINING WALL4A-63A-66A-61A-62'-10"4'-2"NEW FRP4'-2"NEW FRP6'-10"NEW AWNING (TO MATCH EXISTING)EXISTING AWNING, (3) TOTALTO BE REMOVED(SHOWN HIDDEN)PROPERTY LINERIGHT OF WAY"ALPHA" S E C T O R 1 0 5 °"BETA" SECTOR 210°5A-6NEW VERIZON WIRELESS DUALDIPLEXERS, (2) PER SECTOR,TOTAL OF (4)2A-6NEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)1'-0"NEW VERIZON POWER AND FIBERWEATHER HEADS(MIN. 1FT SEPARATION)Item 8.a. - Page 15 NEW & EXISTINGSOUTHEASTELEVATIONS21/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-4NEW SOUTHEAST ELEVATION11/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSTOP OF NEW VERIZON WIRELESS FRP SCREEN (FAUX AWNING)ELEV. 20' AGLGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLEXISTING SOUTHEAST ELEVATIONEXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 19'-10" AGLRAD CENTER OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 18'-10" AGLNEW VERIZON WIRELESSEQUIPMENT AREA(BEHIND, LOCATED ATREAR OF BUILDING)1A-3NEW VERIZON WIRELESS RRUS,(4)TOTAL, MOUNTED TO EXISTINGBUILDING (SHOWN HIDDEN)NEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')NEW VERIZON WIRELESSCONDUIT PENETRATIONS6A-6TOP OF EXISTING PARAPET WALLELEV. 22.9' AGLNEW VERIZON WIRELESS PANELANTENNAS MOUNTED BEHINDNEW FRP SCREEN (FAUXAWNING), (2) TOTAL1A-6EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLBOTTOM OF NEW VERIZON WIRELESSFRP SCREEN (FAUX AWNING)ELEV. 17'-0" AGL5A-6NEW VERIZON WIRELESS DUALDIPLEXERS, (2) PER SECTOR,TOTAL OF (4)2A-6TOP OF EXISTING FACADE PEAKELEV. 26.4' AGLItem 8.a. - Page 16 21/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'A-5NEW SOUTHWEST ELEVATION11/4" = 1'-0" (24x36)(OR)SCALE:1/8" = 1'-0" (11x17)01'2' 4'NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSGROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLEXISTING SOUTHWEST ELEVATIONTOP OF EXISTING BUILDING (LOWER)ELEV. 17' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLTOP OF EXISTING PARAPET WALLELEV. 22.9' AGLNEW & EXISTINGSOUTHWESTELEVATIONSNEW VERIZON WIRELESS RRUS, (4)TOTAL,MOUNTED EXISTING BUILDING (SHOWNHIDDEN)EXISTING BUILDING IN FOREGROUND(SHOWN AS SECTION THROUGH)GROUND LEVELAGL = 0.0'AGL 0.0' = AMSL 126.1'EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLEXISTING ELECTRICAL METERSNEW VERIZONWIRELESSEQUIPMENT CABINETMOUNTED ON NEWCONCRETE PADLOCATED ATGROUND LEVELNEW VERIZON WIRELESS FIBER, DCPOWER & GROUND CONDUITS ONSLEEPERS (APPROX. 100')NEW VERIZON WIRELESS CONDUITPENETRATIONSEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGEXISTING OVERHEADPOWER LINE TO EXISTINGWEATHER HEAD MOUNTEDTO EXISTING BUILDINGNEW VERIZON WIRELESSGPS ANTENNA MOUNTED(ABOVE) ON EXISTINGBUILDING6A-64A-63A-6EXISTING ROOF LINE (LOWER)ELEV. 10.4' AGLNEW VERIZON WIRELESS PANEL ANTENNAS MOUNTEDBEHIND NEW FRP SCREEN (FAUX AWNING), (2) TOTAL1A-6EXISTING AWNING, (3) TOTALTO BE REMOVED (SHOWNHIDDEN)TOP OF EXISTING PARAPET WALLELEV. 22.9' AGL5A-6TOP OF NEW VERIZON WIRELESS FRP SCREEN (FAUX AWNING)ELEV. 20' AGLEXISTING ROOF LINE (UPPER)ELEV. 19.9' AGLTOP OF EXISTING FACADE PEAKELEV. 26.4' AGLNEW VERIZON POWER/FIBEROVERHEAD LINES TO NEWWEATHER HEADS MOUNTEDTO EXISTING BUILDING(LENGTH=±100FT)NEW VERIZON POWER AND FIBERWEATHER HEADS(MIN. 1FT SEPARATION)TOP OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 19'-10" AGLRAD CENTER OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 18'-10" AGLBOTTOM OF NEW VERIZON WIRELESS ANTENNASELEV. 17'-0" AGL1'-4"Item 8.a. - Page 17 DETAILSA-63N.T.S.SCALE2N.T.S.SCALE8N.T.S.SCALE1N.T.S.SCALENOT USEDNOT USED7N.T.S.SCALENOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZESSHEET TITLE:ISSUE STATUSPROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITEDSAN DIEGO, CA 92122619.736.37665015 SHOREHAM PL, SUITE 150www.sacw.comSAC AE DESIGN GROUP, INC.W I R E L E S S2875 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598DESCRIPTIONDATE BYREV.0OMSMALL CELL PROJECT119 & 121 E. BRANCH ST.ARROYO GRANDE, CA 93420PSL # 285338DT ARROYOGRANDE SC15/1/2019 PLANNING SUBMITTAL1OM6/6/2019 PLANNING COMMENTSANTENNA DETAIL5N.T.S.SCALERADIO DETAIL4N.T.S.SCALEEQUIPMENT CABINET DETAILERICCSON 4449DIMENSIONS:HEIGHT: 15"WIDTH: 13.2"DEPTH: 9.3"WEIGHT: 70LBS#2 AWG BTCW(TYP. 3 PLACES)GPS ANTENNA1-1/4"Ø PIPECABLE TO PIPE CONNECTORBURNDY TYPE GARTOP OFPARAPET WALLCONTINUOUS BEAD OFSILICONE SEALANT @TOP OF UNISTRUT, TYP.12" MIN. LENGTHUNISTRUT P1000, TYP.CONDUIT CLAMPNEOPRENE WASHER @THREADED ROD, TYP.#6 AWG GROUNDINGCABLE KIT1/2"Ø COAXIAL CABLESECURE TO WALL USINGHILTI CONCRETE SCREWS,1/4"Ø X 1-3/4" LONGCOPPER ISOLATEDGROUND BUSUNISTRUT HEXHEAD CAPSCREW (TYP)NEW 3-1/2" ODGALVANIZED PIPECOLUMNNEW 1/2" U-BOLT, A307OR BETTERNEW P2800-50 U-SHAPEFITTING (TYP. OF 2 PERU-BOLT)UNISTRUT SPRING NUT(MIN. OF 4 PLACES)1/2" HEX NUT1"Ø x 1/8" WASHERP1000 UNISTRUTCABINET(7) 1.75" / 2.5"KNOCKOUT(BOTH SIDESOF CABINET)CHARLES UNIVERSAL BROADBAND ENCLOSURE (CUBE) SS4C215DB3REGULATORY SPECIFICATIONS:WEIGHT (W/ BATTERIES)RACK MOUNTINGCOLORMATERIAL73"H x 32"W x 32"D 740LBS23" (15RU)OFF WHITE.125" WELDED ALUMINUMMOUNTING STYLEPAD MOUNT ENCLOSUREDOOR LATCHING3-POINT LATCHING WITH PAD LOCKABLE HANDLEBATTERY TYPES / TERMINATION Ni-CD OR VRLA, ANDERSON DISCONNECTS FOR EACH STRINGAC TERMINATION12 POSITION LOAD CENTER (LEFT HAND SIDE)BUS BARSTWO (2) 2X14 POSITION BUS BARS(7) 1.75/2.5" DOUBLE KNOCKOUT ON RHS(7) 1.75/2.5" DOUBLE KNOCKOUT ON LHS(4) 1.75/2.5" DOUBLE KNOCKOUT ON REARCABLE ENTRANCEALARMSDOOR INTRUSION (2)CERTIFICATIONSTELCORDIA ZONE 4 SEISMIC, TELCORDIA GR-487 AND ULDIMENSIONS AND WEIGHT (W/ OUT BATTERIES)1811LBS32.132.132.332.3FRONT VIEWSIDE VIEWPLAN VIEW74.1"72.3"6.9"5.4"3.5"3.2"8.1"14"2.7"LENGTH: 23.2"WIDTH: 12.0"DEPTH: 7.1"WEIGHT: 13 LBSAMPHENOLHTXCWW63111414Fxy012"23.2"7.1"FOR MOUNTING USE:2-POINT MOUNTING &DOWNTILT BRACKETKIT -AMPHENOLPART # 36210006FRONTSIDEGPS DETAILS6N.T.S.SCALEMOUNTING DETAIL9.3"15"FRONTSIDETOP13.2"11.1"15"FRONTSIDETOP13.2"ERICCSON 8843DIMENSIONS:HEIGHT: 15"WIDTH: 13.2"DEPTH: 11.1"WEIGHT: 75LBSRADIO DETAILDIPLEXER SPECIFICATIONSItem 8.a. - Page 18